Atomizer: Air-C2H2 Flame
Elements: Ag, Au, Ba, Bi, Ca, Cd, Co, Cr, Cs, Cu, Fe, Ga, In, K, Li, Mg, Mn, Mo, Na, Ni, Pb, Pd, Pt, Rb, Rh, Sb, Sn, Sr, Te, Tl, Zn
Hydrid Generation atomizer
Elements: As, Se, Sb, Bi, Pb, Sn, Te, Ge, Hg
Wavelength range 190-900nm
Wavelength accuracy ±0.5nm
Resolution
Two spectral lines of Mn at 279.5nm and 279.8nm can be
separated with the spectral bandwidth of 0.2nm and
valley-peak energy ratio less than 30%.
Baseline stability 0.005A/30min
onochomator Single beam, Czerny-Turner design grating monochromator
Grating 1800 l/mm
Focal length 277mm
Blazed wavelength 250nm
Spectral bandwidth 0.1 nm, 0.2nm, 0.4nm, 1.2nm, 4 steps
Adjustment Manual adjustment for wavelength and slit
SPECIFICATIONS |
---|
Main Specification | Wavelength range | 190-900nm | Wavelength accuracy | ±0.25nm | Resolution | Two spectral lines of Mn at 279.5nm and 279.8nm can be separated with the spectral bandwidth of 0.2nm and valley-peak energy ratio less than 30%. | Baseline stability | ≤0.004A/30min | Background correction | The D2 lamp background correction capability at 1A is better than 30 times. The S-H background correction capability at 1.8A is better than 30 times. ( only for AAS-110A/120A) | Light Source System | Lamp turret | 6-lamp turret (AAS-110A/120A), 4-lamp turret (AAS-130A) Auto-alignment, fully automated scan and peak-picking. | Lamp current adjustment | Automatic adjustment and display. Wide pulse current: 0~25mA, Narrow pulse current: 0~10mA | Lamp power supply mode | 400Hz square wave pulse; 100Hz narrow square wave pulse + 400Hz wide square wave pulse ( AAS-110A/120A ) | Optical System | Monochromator | Single beam, Czerny-Turner design grating monochromator | Grating | 1800 l/mm | Focal length | 277mm | Blazed wavelength | 250nm | Spectral bandwidth | 0.1 nm, 0.2nm, 0.4nm, 1.2nm, automatic change. | Flame Atomizer | Burner | 10cm single slot all-titanium burner | Spray chamber | Corrosion resistant all-plastic spray chamber. | Nebulizer | High efficiency glass nebulizer with metal sleeve. sucking up rate: 6-7mL/min | Emission burner | Provided with AAS-110A/120A | Graphite Furnace | Temperature range | Room temperature-3000°C | Heating rate | 2000°C/s | Graphite tube dimensions | 28mm (L) x 8mm (OD) | Characteristic mass | Cd≤0.8*10-12g, Cu≤5*10-12g, Mo≤1*10-11g | Precision | Cd≤3%, Cu≤3%, Mo≤4% | Detection and Data Processing System | Detector | R928 photomultiplier with high sensitivity and wide spectral range. | Software | Windows operating system | Analytical method | Working curve auto-fitting; standard addition method; automatic sensitivity correction; automatic calculation of concentration and content. | Repeat times | Maximum 20 times of repeat measurement, automatic calculation of mean value, standard deviation and relative standard deviation. | Multi-task function | Sequential measurement of multi-elements in one sample. | Condition reading | With model function | Result printing | Measurement data and final analytical report printout, editing with Excel. | Standard RS-232 serial port communication | Characteristic Concentration and Detection Limit | Normal Air-C2H2 flame | Cu: Characteristic concentration ≤ 0.025 mg/L, Detection limit≤0.006mg/L; | Rich oxygen Air-C2H2 flame | Ba: Characteristic concentration ≤ 0.22mg/L AI: Characteristic concentration ≤ 0.4mg/L (for AAS-110A ) | Function Expansion | Hydridee vapor generator can be connected for Hydridee analysis. | Dimensions and Weight | 1020 (L) x 490 (W) x 540 (H) mm (main unit), unpacked 80kg 420 (L) x 420 (W) x 460 (H) mm (graphite furnace), unpacked 50kg |
Model | 02-enrichedflame*1 | Flameemission | The number of HCL*2 | AutoAlignment | HP-HCL*3 | Background correction | Autosampler | PC control | Flow rate control | Atomizer |
---|
AAS-210 | Yes | Yes | 6 | Yes | Yes | S-H, D2 | Yes | Yes | Automatic | Air-C2H2 Flame*4 | 02-enriched Flame*1 | Graphite Furnace*4 | Hydride Generation*5 | AAS-110A | Yes | Yes | 6 | Yes | Yes | S-H, D2 | No | Yes | Manual | Air-C2H2 Flame | 02-enriched Flame | Graphite Furnace | Hydride Generation | AAS-120A | No | Yes | 6 | Yes | Yes | S-H, D2 | No | Yes | Manual | Air-C2H2 Flame | Graphite Furnace | Hydride Generation | AAS-130A | No | No | 4 | Yes | No | D2 | No | Yes | Manual | Air-C2H2 Flame | Graphite Furnace | Hydride Generation | AAS-110B | Yes | Yes | 6 | Yes | Yes | S-H, D2 | No | Yes | Manual | Air-C2H2 Flame | 02-enriched Flame | Hydride Generation | AAS-120B | No | Yes | 6 | Yes | Yes | S-H, D2 | No | Yes | Manual | Air-C2H2 Flame | Hydride Generation | AAS-130B | No | No | 4 | Yes | No | D2 | No | Yes | Manual | Air-C2H2 Flame | Hydride Generation | AAS-320 | No | No | 4 | No | No | D2 | No | No | Manual | Air-C2H2 Flame | Hydride Generation |
|
|
Questions?